The interlocking technology used on the koramic 401 flemish pantile allows it to go a fraction lower at 22.
Redland roof tile minimum pitch.
Linear cover of 1 tile.
Bmi redland draws on the expertise and experience gathered from nearly 100 years as an industry leader.
90 subject to fixing specification.
The minimum pitch may also be affected by the presence of roof features such as dormers roof windows and chimneys.
Adjacent tiles should be laid with a nominal gap of 1 5 mm maximum 3 mm.
12 5 17 5 at 100 mm headlap at 75 mm headlap minimum pitch 15 if roof slope includes valleys maximum pitch.
At eaves use double courses with purpose made eaves top tiles for the undercourse.
The minimum pitch is based on a maximum rafter length of 10 metres.
125 mm minimum gauge.
The minimum pitch may also be affected by the presence of roof features such as dormers roof windows and chimneys.
Adjacent tiles should be laid with a nominal gap of 1 5 mm maximum 3 mm.
From roof tiles and underlays to eaves systems and ridges bmi redland have a comprehensive range of roof products and systems.
A smaller format offers a light unit weight and a tile that is easy to handle and install.
25 mm hanging length.
Naturally this ideal befits the name because the clay of every two piece redland tile is truly of the earth.
A harmonious union with the very land that helped create it.
Minimum pitch headlap.
Where the minimum pitch for clay pantiles used to be 30 tiles like the redland cathedral pantile can be pitched as low as 22 5.
From the heart of the land.
At verges and abutments use standard plain tiles and tile and a halves in alternate courses.
All elements of bmi redland roofs are carefully designed tested and manufactured to give value visual appeal and a long lasting weathertight performance.
At eaves use double courses with purpose made eaves top tiles for the undercourse.
Our range of tiles slates renewable energy systems fittings and accessories combined with market leading technical support services enable us to deliver total pitched roofing solutions you can rely on.
For rafter lengths greater than this telephone technical solutions on 03708 702595 for advice.
At verges and abutments use standard plain tiles and tile and a halves in alternate courses.
Adjacent to hips and valleys use tile and a halves for raking cuts.
The redland 49 has defined the roofscapes of london for over half a century with its unique camber adding both strength and aesthetic appeal.
The minimum pitch is based on a maximum rafter length of 10 metres.
293 mm maximum gauge.
As a result personality was always a part of the handmade process.
For rafter lengths greater than this telephone technical solutions on 03708 702595 for advice.
Below 17 5 17 5 and over.
Historically clay tile was formed by hand.